Second metatarsal (2MT) stress fracture is a common and burdensome injury amongst runners, however understanding of the risk factors leading to injury is limited. Finite Element (FE) modelling represents a viable biorealistic alternative to invasive studies and simple beam theory models. This study ...
Determining weights among terms in the cost function for walking was formulated as a bilevel optimization problem (BLO). The direct collocation (DC) method effectively solved the lower level problem, making it practical to solve the BLO using a nested evolutionary approach.
Running Specific Prostheses (RSP) used by amputee athletes for sprinting and long jumping have a large effect on athlete performance and health. This study reports about the development and test of a set of instrumented RSP (iRSP) that could be used on the field for data collection of block start, s...
Modern wearable fitness trackers contain on-device inertial measurement units (IMUs) that measure user activity metrics. These trackers, however, typically require access to a GPS-enabled device (such as a smartphone) to measure speed and distance. This presents a problem when GPS signal is sparse o...
Quantitative measures related to mechanical strength of the anterior cruciate ligament (ACL) graft are needed for timely return-to-sports decisions after the ACL reconstruction surgery (ACLR). Ultra-short echo-time (UTE)-T2* magnetic resonance imaging (MRI) was used to study structural changes in gr...
Acquiring the shape of foot plantar surface is critical to perform anatomical measurements, for objective diagnosis of foot morphological alterations and to design custom orthotics and footwear. Whereas laser scanners are currently the gold-standard for accurate 3D digitization of body parts, these ...
In this paper it is presented a simplified cost function (CF) that can be used to determine the pedaling cadence that minimizes the muscular stress in cycling. With respect to similar CF, the proposed one requires less experimental data to be calculated, thus it can be preferable in the characteriza...
A framework is proposed to develop an inhomogeneous Finite-Element (FE) model of a human proximal humerus fracture (PHF) with an osteosynthesis device in order to characterize the overall stiffness and load to failure properties under physiological-like loading/test conditions. An experimental set-u...
Instrumented mouthguards are used to record in-vivo head kinematics in sport. The validation of the CSx mouthguard’s capacity to measure linear acceleration was assessed using impact testing versus a reference single-axis accelerometer. The CSx mouthguard’s linear acceleration demonstrated favou...
Hip muscle weakness is a risk factor for many musculoskeletal injuries to the hip and groin region. Instruments used to measure hip muscle strength are designed to assess muscle actions in a single plane, which is not consistent with the multiplanar line of action of many hip muscles. This study aim...
This paper discusses challenges and opportunities for biomechanics researchers who are integrating wearable sensor data with biomechanical modelling or machine learning approaches in the context of understanding injury mechanisms. Example applications include a framework for integrating body worn in...
Prospective authors are invited to submit manuscripts reporting original unpublished research and recent developments in the topics related to the conference. It is required that the manuscript follows the standard IEEE camera-ready format (IEEE standard format, double column, 10-point font). Submis...
We examined the functional role of intramuscular coherence in relation to changes in spatiotemporal gait parameters during split-belt walking adaptation. We found that corticospinal drive measured by intramuscular coherence in the tibialis anterior muscle changed with adaptation, and that increased ...
The paper presents an example of a successful use of 3D motion analysis for forensic purposes, and tries to show the cases in which this analysis is helpful and offers opportunities to law enforcement agents. In the present case of a shotgun hunter a fundamental question was asked - was there someon...
This presentation follows up the keynote presentation of the Teaching Symposium, which highlighted the benefits of engaging students in the classroom through the use of active learning techniques. In this presentation, we focus on the “Jigsaw” technique and share one easily adaptable classroom a...
The objective of this study was to evaluate the accuracy of a commercially available low cost inertial motion capture system (IMC). Four subjects equipped with seventeen inertial measurement units (IMU) performed manual handling of boxes for about 35 minutes. An optoelectronic system was used as a g...
A human activity recognition system using wearable sensor data that can detect dance specific activities (jumping and leg lifting tasks) and quality of movement, such as ground reaction force was developed, using a machine learning approach. This system allows for the measurement of specific trainin...
Using our lab’s biplane fluoroscopy system, we collected data on eight bone phantoms to assess the accuracy of our custom bead-based and model-based tracking algorithms. Custom rigs were constructed to apply uniaxial rotation and translation to these bone phantoms. External potentiometer measureme...
The purpose of this research was to validate wireless inertial sensor measures of hip joint orientation during dynamic tasks. Inertial sensor derived hip joint angles (found using acceleration, angular velocity, and magnetic field data) are compared to those found using a 3D camera-based laboratory ...
This study compared video-based joint angle and reach envelope measures for simulated working tasks to motion capture and to physical demands description estimates from novice and experienced ergonomists. Video-based measures showed low RMS error and high weighted Cohen’s kappa scores, and demonst...
Traditionally, sensors used to control powered prostheses have either been incorporated into the residual limb or built into the socket that is worn by the user—no additional instrumentation is required to control the prosthesis. Minimizing instrumentation was viewed as a requirement for clinical ...
In vivo muscle biomechanical properties have been classically inferred from inverse dynamics or measurements of joint torque performed using ergometers. These measures provide information about the combined behavior of several structures (e.g., muscles, tendons, nerves, skin) acting around a given j...
Knee braces have been proposed to prevent anterior cruciate ligament (ACL) injuries, and musculoskeletal (MS) models can be used to assess the effect of such braces on joint mechanics. Therefore, the aim of this study was to use MS simulations to estimate the effect of an in silico ACL injury preven...
To better understand the effects of fatigue on running biomechanics, data were collected using an inertial measurement unit (IMU) for 28 subjects running a marathon race. During one marathon, however, one male recreational runner sustained a running-related injury in his left calf muscle and retired...
Walking deficits are common following stroke, yet typically used clinical and functional assessments fail to adequately identify their source. We previously developed a Comprehensive Locomotion Index (CLI) that uses objective measurements and differentiates functional status among individuals with c...
Biomechanics simulators must be validated before use to ensure accuracy and confidence in all future studies. A novel biomechanics simulator was validated with the use of optical motion tracking. The application of pure moments and accurate displacement control was confirmed.
Participants’ kinematics were collected using two motion capture systems (Xsens (inertial), Vicon (optical)) while performing a series of occupationally-relevant military-based movements. Principal component analysis (PCA) was used to detect variance within the three-dimensional marker trajectorie...
Motion capture systems are useful tools for assessing different aspects of human movement. 3D systems are the preferred method as they utilize multiple cameras to gather accurate and reliable measurements. They can be cost-prohibitive and complex to use. In the absence of a 3D system, a 2D system ca...
The purpose of this study was to determine the validity and reliability of a clinic-based treadmill with integrated markerless motion capture. Hip and knee angular measures had moderate to high between-day reliability. However, caution should be exhibited interpreting joint angles from this clinic-b...
The present study examines the validity and reliability of a depth-camera based approach for segment lengths estimation of the pelvis and the lower extremity. For the evaluation, a Kinect sensor and an optical motion capture system were used to automatically deduce the segment lengths of young subje...